Control with phase angle technology
4A AC or 15A AC load current
Selectable 110V AC or 220V AC load voltage
Selectable 50Hz or 100Hz vibration frequency
Phase angle can be controlled by adjustment knob or 0-10V DC analog signal
Load output can be stopped with digital input
Selectable digital input (for NO/NC contact or NO/NC sensor)
Power cable with plug and motor connection cable included
Connection cable for digital input
Maximum and minimum value can be assigned to output
Internal fuse
4 digits LED indicator
Soft Start feature
Varistor protection for voltage peaks
On/Off Power switch
CE marked according to European Norms
Environmental Conditions
Ambient/Storage Temperature – 0…50 ºC / -25…60 ºC
Relative Humidity – 80% relative humidity for temperatures up to 31 °C, decreasing linearly to 50% at 40 °C
Protection Degree – According to EN 60529 IP20
Height – Max. 2000m
Input
Supply – 90-250V AC, 50/60Hz, 600VA
Digital Input – Load output stopping method can be selected from program (NO/NC contact or NO/NC sensor)
Internal 12V DC output or an external 10-30V DC supply can be used
Insulation Voltage – 2500 Vrms 1 minute between input and output terminals
External Connections – Plug-in terminals
Output
Load Current, AC51/25°C (Arms) – 4A AC or 15A AC
Load Voltage (Vrms) – 110V AC or 220V AC, selectable by (JP1) jumper
Vibration Frequency – 50/60Hz or 100/120Hz, selectable by (JP1) jumper
Overload Current t=1s/25°C (Arms) – 150
Nonrecurrent Surge Current/25°C (Arms) – 400
Voltage Drop in Transmission (Vrms) – 1,6
Leakage Current (mArms) – 5
I²t Value for Fuse t=10ms (A²s) – 880
Frequency (Hz) – 50-60
Power Factor (CosØ) – >0,75
Minimum Operating Current (mArms) – 160
Control
Type : temperature, condition for machines, pressure, humidity, vibration, light intensity, noise level
Applications : for machines
Interface : Ethernet
Other characteristics : wireless, remote, robust, IoT, cloud-based hazard
Reviews
There are no reviews yet.