ELECTRODYNAMIC® APPROVED PARTICULATE CEM
MCERTS EN 15859 Filter Dust Approved Particulate monitoring system providing high quality emission measurement for low dust concentrations from dry industrial processes including Baghouses and Cartridge Filters
FEATURES & BENEFITS
– Robust design unaffected by product build-up on the sensor rod
– No additional services such as air purge required, providing lower cost of ownership
– Simple maintenance no requirement for specialist service personnel
– Networking up to 16 sensor channels via Modbus and providing multiple inputs and outputs for external connections
– Extensively used for measurement (mg/m³) and leak location in bag filter stack applications
– Advanced sensor design includes drift checks (zero and span) and contamination checks
– Passive/Active and fully insulated sensor options available for applications with stack condensation and damp particulate prevents potential short circuit to stack wall
MAIN APPLICATIONS
– Stacks after bag filters, cartridge filters, cyclones, electrostatic precipitators, no filtration
– Non-condensing / dry flue gases
– Variable velocities within range 8 – 20 m/s (typical bag filter velocity ranges), constant velocity required outside this range
– After process dryers
Typical Applications:
– Incineration
– Metals (eg Steel/Aluminium)
– Minerals (eg Cement/Gypsum)
– Chemicals (eg Detergent / Carbon Black)
– Power Generation Plant (eg Coal/Biomass)
Applications : particle, (CEMS) continuous emission
Other characteristics : automatic
Reviews
There are no reviews yet.